| Fall Protection System |
Compliance Codes |
 |
Steel Non-penetrating Guardrails |
Federal OSHA:
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Steel Non-penetrating Guardrails |
Federal OSHA:
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
|
 |
Steel Non-penetrating Guardrails (Modular) |
Federal OSHA:
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.29(b) and 1926.502(b)
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Aluminum Non-penetrating Guardrails (Modular) |
Federal OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Aluminum Non-penetrating Weighted Base Guardrails (Modular) |
Federal OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Fixed Mounted Guardrails |
Federal OSHA:
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Steel Fixed Guardrails for Metal Decks (Modular) |
Federal OSHA:
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.29(b) and 1926.502(b)
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Aluminum Fixed Top Mounted Guardrails (Modular) |
Federal OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Aluminum Fixed Side Mounted Guardrails (Modular) |
Federal OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance: OSHA 1910.29 and 1926.502
|
Cal-OSHA / WA-OSHA:
- Maximum Post Spacing: 8ft. on center (96in.)
- Compliance (CA): Cal-OSHA Title 9, 1620 and 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
|
 |
Forklift Rated Protective Guardrail |
Federal OSHA:
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.176(a), ANSI MH31.2-201
|
Cal-OSHA / WA-OSHA (same as Fed OSHA):
- Maximum Post Spacing: 10ft. on center (120in.)
- Compliance: OSHA 1910.176(a), ANSI MH31.2-201
|
 |
Gate & Guardrail Kit for Roof Ladder |
Federal OSHA:
- Compliance: OSHA 29 CFR 1910.23 (a) (2), 29 CFR 1910.23 (c) (1), 29 CFR 1926.502
- American Welding Society Certified (AWS D1.1 & D1.3)
|
Cal-OSHA / WA-OSHA:
- Compliance (CA & WA): OSHA 29 CFR 1910.23 (a) (2), 29 CFR 1910.23 (c) (1), 29 CFR 1926.502
- American Welding Society Certified (AWS D1.1 & D1.3)
|
 |
Gate & Guardrail Kit for Work Area |
Federal OSHA:
- Compliance: OSHA 29 CFR 1910.29 and CFR 1926.502
- American Welding Society Certified (AWS D1.1 & D1.3)
|
Cal-OSHA / WA-OSHA:
- Compliance (CA): Cal-OSHA Title 8, Chapter 4, Article 19, 3212; 3209
- Compliance (WA): WA-OSHA WAC 296-24-75011
- American Welding Society Certified (AWS D1.1 & D1.3)
|