Fixed Roof Dome Skylight Screens

CAI Safety provides Fixed Dome Skylight Safety Screens that are OSHA and CAL-OSHA fall protection compliant. They fit a variety of dome-shaped skylights and don’t take up any space on the roof. Our unique compression-fit design locks the screen onto the aluminum frame of the skylight.

PLEASE NOTE: Maximum Cal-OSHA compliance size is Width 53” x Length 120”. Any skylight dimensions exceeding these will require us to quote you separately. Please contact us.

Dome Height from skylight curb to the top of the dome. Please refer to the ‘Sizing Your Skylight’ tab on this page)
e.g. 15in or 15″
Dome Height of Skylight

SKU: SRCPLA-DOMESKY Category: Tag:

Description

CAI Safety provides Fixed Skylight Safety Screens that are OSHA and CAL-OSHA fall protection compliant. They fit a variety of dome-shaped skylights and don’t take up any space on the roof. Our unique compression-fit design locks the screen onto the aluminum frame of the skylight.

Skylight Screens often are the most economical solution for guarding skylights. The Skylight Screens are available in a range of sizes and configurations to retrofit your skylights. Best of all, they do not require any penetrations to the roof, curb, or skylight.

PLEASE NOTE: Maximum Cal-OSHA compliance size is Width 53” x Length 120”. Any skylight dimensions exceeding these will require us to quote you separately. Please contact us.


FEATURES & BENEFITS

  • Economical
  • Compression-fit — no penetrations
  • Galvanized finish
  • Perfect for high wind areas
  • OSHA compliance for all widths and lengths
  • CAL-OSHA compliance for all widths and lengths

**CAUTION WARNING** This is a fall protection system. The system must be used in strict conformance with the manufacturer's instructions. Failure to do so may result in serious injury or death. You can download the system manuals from the 'Downloads' tab. You are also encouraged to contact us in case of any questions.

Measure the actual length and width of your skylight and then use the pull down menu at the top of this page to size a fall protection cover for your skylight.

Skylight Cover Guard - Sizing Your SkylightMeasuring_A_Skylight

All Widths All Lengths Description CAL-OSHA
24″, 30″, 36″, 42″, 48″, 53″ 24″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 30″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 36″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 42″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 48″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 54″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 60″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 66″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 72″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 78″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 84″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 90″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 96″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 102″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 108″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 114″ Fits square & rectangular skylights Compliant
24″, 30″, 36″, 42″, 48″, 53″ 120″ Fits square & rectangular skylights Compliant
24″-28″ (2′) W 24″-28″ (2′) L Fits square skylights Compliant
36″-40″ (3′) W 36″-40″ (3′) L Fits square skylights Compliant
48″-52″ (4′) W 48″-52″ (4′) L Fits square skylights Compliant
58″-62″ (5′) W 58″-62″ (5′) L Fits square skylights Not Compliant
72″-76″ (6′) W 72″-76″ (6′) L Fits square skylights Not Compliant
78″-88″ (7′) W 78″-88″ (7′) L Fits square skylights Not Compliant
96″-100″ (8′) W 96″-100″ (8′) L Fits square skylights Not Compliant
24″-28″ (2′) W 48″-52″ (4′) L Fits rectangular skylights Compliant
24″-36″ (2′) W 94″-100″ (8′) L Fits rectangular skylights Compliant
36″-40″ (3′) W 48″-52″ (4′) L Fits rectangular skylights Compliant
36″-40″ (3′) W 72″-76″ (6′) L Fits rectangular skylights Compliant
48″-52″ (4′) W 72″-76″ (6′) L Fits rectangular skylights Compliant
48″-52″ (4′) W 94″-100″ (8′) L Fits rectangular skylights Compliant
60″-64″ (5′) W 72″-76″ (6′) L Fits rectangular skylights Not Compliant
60″-64″ (5′) W 94″-100″ (8′) L Fits rectangular skylights Not Compliant
72″-76″ (6′) W 94″-100″ (8′) L Fits rectangular skylights Not Compliant
SKU’s Downloads
SRC-DSS-24-24 SRC-DSS-42-36 SRC-DSS-24-54 SRC-DSS-42-66 SRC-DSS-24-84 SRC-DSS-42-96 SRC-DSS-24-114
SRC-DSS-30-24 SRC-DSS-48-36 SRC-DSS-30-54 SRC-DSS-48-66 SRC-DSS-30-84 SRC-DSS-48-96 SRC-DSS-30-114
SRC-DSS-36-24 SRC-DSS-53-36 SRC-DSS-36-54 SRC-DSS-53-66 SRC-DSS-36-84 SRC-DSS-53-96 SRC-DSS-36-114
SRC-DSS-42-24 SRC-DSS-24-42 SRC-DSS-42-54 SRC-DSS-24-72 SRC-DSS-42-84 SRC-DSS-24-102 SRC-DSS-42-114
SRC-DSS-48-24 SRC-DSS-30-42 SRC-DSS-48-54 SRC-DSS-30-72 SRC-DSS-48-84 SRC-DSS-30-102 SRC-DSS-48-114
SRC-DSS-53-24 SRC-DSS-36-42 SRC-DSS-53-54 SRC-DSS-36-72 SRC-DSS-53-84 SRC-DSS-36-102 SRC-DSS-53-114
SRC-DSS-24-30 SRC-DSS-42-42 SRC-DSS-24-60 SRC-DSS-42-72 SRC-DSS-24-90 SRC-DSS-42-102 SRC-DSS-24-120
SRC-DSS-30-30 SRC-DSS-48-42 SRC-DSS-30-60 SRC-DSS-48-72 SRC-DSS-30-90 SRC-DSS-48-102 SRC-DSS-30-120
SRC-DSS-36-30 SRC-DSS-53-42 SRC-DSS-36-60 SRC-DSS-53-72 SRC-DSS-36-90 SRC-DSS-53-102 SRC-DSS-36-120
SRC-DSS-42-30 SRC-DSS-24-48 SRC-DSS-42-60 SRC-DSS-24-78 SRC-DSS-42-90 SRC-DSS-24-108 SRC-DSS-42-120
SRC-DSS-48-30 SRC-DSS-30-48 SRC-DSS-48-60 SRC-DSS-30-78 SRC-DSS-48-90 SRC-DSS-30-108 SRC-DSS-48-120
SRC-DSS-53-30 SRC-DSS-36-48 SRC-DSS-53-60 SRC-DSS-36-78 SRC-DSS-53-90 SRC-DSS-36-108 SRC-DSS-53-120
SRC-DSS-24-36 SRC-DSS-42-48 SRC-DSS-24-66 SRC-DSS-42-78 SRC-DSS-24-96 SRC-DSS-42-108
SRC-DSS-30-36 SRC-DSS-48-48 SRC-DSS-30-66 SRC-DSS-48-78 SRC-DSS-30-96 SRC-DSS-48-108
SRC-DSS-36-36 SRC-DSS-53-48 SRC-DSS-36-66 SRC-DSS-53-78 SRC-DSS-36-96 SRC-DSS-53-108
* PLA-SM1-SQ5 * PLA-SM1-SQ6 * PLA-SM1-SQ7 * PLA-SM1-SQ8 * PLA-SM1-RC4 * PLA-SM1-RC5 * PLA-SM1-RC6
PLA-SM1-RC7

* Not CAL-OSHA Compliant

Federal OSHA and Cal OSHA are specific on performance standards for railings, screens and covers for skylights. Paramount for all of them is that if a person falls onto the screen or cover they must not be allowed to break the lens of the skylight. In other words the screen or cover must not only support the weight of the person falling, it must also meet load requirements prescribed by OSHA. If using railings, the railing must meet load requirements of their own. Here are the pertinent standards from the https://www.osha.gov/ website by which skylight guarding is mandated by law and that all railings, covers and screens must comply.

——–

Federal OSHA: General Industry (29 CFR 1910.29) and Construction (29 CFR 1926.501 & 1926.502)

Cal-OSHA: Title 8, Section 3212 and Title 8, Section 1632

ANSI: A1264.1 and Z359.1

——–

29 CFR §1910.23
Guarding Floor and Wall Openings and Holes.
(a)(4) Every skylight floor opening and hole shall be guarded by a standard skylight screen or a fixed standard railing on all exposed sides.

(e)(8) Skylight screens shall be of such construction and mounting that they are capable of withstanding a load of 200 pounds applied perpendicular at any one area of the screen. They shall also be of such construction and mounting that under ordinary loads or impact, they will not deflect downward sufficiently to break the glass below them. The construction shall be of grillwork with openings not more than 4 inches long or slab work with openings not more than 2 inches wide with length unrestricted.

29 CFR §1926.501
Duty to have fall protection.
(a) General. (1) This section sets forth requirements for employers to provide fall protection systems. All fall protection required by this section shall conform to the criteria set forth in 1926.502 of this subpart. (a)(2) The employer shall determine if the walking/working surfaces on which its employees are to work have the strength and structural integrity to support employees safely. Employees shall be allowed to work on those surfaces only when the surfaces have the requisite strength and structural integrity.

(b)(4) Holes. (i) Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. (ii) Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers. (iii) Each employee on a walking/working surface shall be protected from objects falling through holes (including skylights) by covers.

At CAI Safety Systems all of our products meet the appropriate standards. They are made in the USA by AWS Certified Welders under strict quality control standards.

By providing some basic information, we can provide you with a custom quotation or more product information.
If you prefer to speak with a fall protection expert just call us at (951) 465-7386 x 303 or email us at [email protected]

These application and system specific forms are highly customized to help you provide system specific information about your fall protection requirements.

Related Products