{"id":11492,"date":"2017-04-18T10:28:04","date_gmt":"2017-04-18T17:28:04","guid":{"rendered":"https:\/\/caisafety.com\/?page_id=11492"},"modified":"2025-10-14T04:19:09","modified_gmt":"2025-10-14T11:19:09","slug":"ansi-fall-protection","status":"publish","type":"page","link":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/","title":{"rendered":"ANSI Fall Protection Regulations &#038; Standards"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"11492\" class=\"elementor elementor-11492\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e228018 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"e228018\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-02945c1\" data-id=\"02945c1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a543b88 elementor-widget__width-initial elementor-widget-tablet__width-inherit elementor-widget-mobile__width-inherit elementor-widget elementor-widget-heading\" data-id=\"a543b88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ANSI Fall Protection Regulations &amp; Standards\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-105c1a3 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"105c1a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/webstore.ansi.org\/industry\/safety-standards\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">ANSI website<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-36a39a2 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"36a39a2\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5562f90\" data-id=\"5562f90\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d67ac96 asi_box elementor-widget elementor-widget-toggle\" data-id=\"d67ac96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2241\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2241\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-angle-down\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M143 352.3L7 216.3c-9.4-9.4-9.4-24.6 0-33.9l22.6-22.6c9.4-9.4 24.6-9.4 33.9 0l96.4 96.4 96.4-96.4c9.4-9.4 24.6-9.4 33.9 0l22.6 22.6c9.4 9.4 9.4 24.6 0 33.9l-136 136c-9.2 9.4-24.4 9.4-33.8 0z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-angle-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M177 159.7l136 136c9.4 9.4 9.4 24.6 0 33.9l-22.6 22.6c-9.4 9.4-24.6 9.4-33.9 0L160 255.9l-96.4 96.4c-9.4 9.4-24.6 9.4-33.9 0L7 329.7c-9.4-9.4-9.4-24.6 0-33.9l136-136c9.4-9.5 24.6-9.5 34-.1z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">GENERAL INFORMATION<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2241\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2241\"><div class=\"osha_img\"><img decoding=\"async\" src=\"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png\" \/><\/div><p>The <a href=\"http:\/\/webstore.ansi.org\/safety_standards\/default.aspx?source=ohs\" target=\"_blank\" rel=\"noopener noreferrer\">American National Standards Institute (ANSI)<\/a> founded in 1918, coordinates the development of voluntary safety standards in the fall protection industry. Representing more than 3.5 million professionals ANSI is comprised of government agencies, organizations, academic and international bodies, and individuals. ANSI Fall Protection regulations are not law, but do provide guidelines that are frequently so practical and essential that they are adopted by OSHA and enforced legally.<\/p><p>ANSI Fall Protection consensus standard was originally published in 1992, and was aimed at providing safety requirements for personal fall arrest systems, subsystems and components. One of the most important issues they have brought to the forefront is the elimination of hazards in the fall protection products themselves. And each time ANSI undergoes a revision, they hold the manufacturers of fall protection products to a higher standard. For example, a connector gate face that was previously compliant at 220 lbs. now is held to 3,600 lbs. This ensures employers and employees that they not only have the highest quality products, but, as a result, the safest workplaces.<\/p><p>ANSI Fall Protection also provides standards for workplace training and appropriate methods for developing a fall protection plan. No other country has such a detailed and comprehensive standard that is specific to fall protection.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2242\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2242\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-angle-down\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M143 352.3L7 216.3c-9.4-9.4-9.4-24.6 0-33.9l22.6-22.6c9.4-9.4 24.6-9.4 33.9 0l96.4 96.4 96.4-96.4c9.4-9.4 24.6-9.4 33.9 0l22.6 22.6c9.4 9.4 9.4 24.6 0 33.9l-136 136c-9.2 9.4-24.4 9.4-33.8 0z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-angle-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M177 159.7l136 136c9.4 9.4 9.4 24.6 0 33.9l-22.6 22.6c-9.4 9.4-24.6 9.4-33.9 0L160 255.9l-96.4 96.4c-9.4 9.4-24.6 9.4-33.9 0L7 329.7c-9.4-9.4-9.4-24.6 0-33.9l136-136c9.4-9.5 24.6-9.5 34-.1z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">ANSI STANDARDS<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2242\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2242\"><table class=\"specs-tab1\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td width=\"460\">Construction and Demolition Operations: Requirements for Safety Belts, Harnesses, Lanyards &amp; Lifelines for Construction and Demolition<\/td>\n<td width=\"250\">A10.14-1991<\/td>\n<\/tr>\n<tr>\n<td width=\"460\">Ladders \u2013 Fixed \u2013 Safety Requirements<\/td>\n<td width=\"250\">A14.3-1992<\/td>\n<\/tr>\n<tr>\n<td width=\"460\">Safety Requirements for Confined Spaces<\/td>\n<td width=\"250\">Z117.1-1989<\/td>\n<\/tr>\n<tr>\n<td>Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components<\/td>\n<td width=\"250\">Z359.1-1992<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2243\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2243\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-angle-down\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M143 352.3L7 216.3c-9.4-9.4-9.4-24.6 0-33.9l22.6-22.6c9.4-9.4 24.6-9.4 33.9 0l96.4 96.4 96.4-96.4c9.4-9.4 24.6-9.4 33.9 0l22.6 22.6c9.4 9.4 9.4 24.6 0 33.9l-136 136c-9.2 9.4-24.4 9.4-33.8 0z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-angle-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M177 159.7l136 136c9.4 9.4 9.4 24.6 0 33.9l-22.6 22.6c-9.4 9.4-24.6 9.4-33.9 0L160 255.9l-96.4 96.4c-9.4 9.4-24.6 9.4-33.9 0L7 329.7c-9.4-9.4-9.4-24.6 0-33.9l136-136c9.4-9.5 24.6-9.5 34-.1z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">ANSI FALL PROTECTION REGULATIONS & STANDARDS<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2243\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2243\"><p>Our ANSI\u00a0compliant Fall Protection, Fall Arrest, and Fall Restraint Systems, including our Fall Protection Training &amp; Services, have been designed to provide ease of handling, installation and use without compromising safety.<\/p><p><strong>ANSI Website:<\/strong>\u00a0<a href=\"https:\/\/webstore.ansi.org\/safety_standards\/default.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/webstore.ansi.org\/safety_standards\/default.aspx<\/a><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2244\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2244\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-angle-down\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M143 352.3L7 216.3c-9.4-9.4-9.4-24.6 0-33.9l22.6-22.6c9.4-9.4 24.6-9.4 33.9 0l96.4 96.4 96.4-96.4c9.4-9.4 24.6-9.4 33.9 0l22.6 22.6c9.4 9.4 9.4 24.6 0 33.9l-136 136c-9.2 9.4-24.4 9.4-33.8 0z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-angle-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M177 159.7l136 136c9.4 9.4 9.4 24.6 0 33.9l-22.6 22.6c-9.4 9.4-24.6 9.4-33.9 0L160 255.9l-96.4 96.4c-9.4 9.4-24.6 9.4-33.9 0L7 329.7c-9.4-9.4-9.4-24.6 0-33.9l136-136c9.4-9.5 24.6-9.5 34-.1z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">ANSI SAFETY REQUIREMENTS FOR PERSONAL FALL ARREST SYSTEMS, SUBSYSTEMS & COMPONENTS<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2244\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2244\"><p>1.2.1 This standard addresses only personal fall arrest systems (PFAS) incorporating full body harnesses. Whenever the term \u201csystem\u201d is used in the standard if refers to a personal fall arrest system.<\/p><p>3.1.2 When subjected to tests contained in 4.2, a personal <a href=\"https:\/\/caisafety.com\/caiss-staging\/mobile-fall-protection-systems\/\">fall arrest system<\/a> in which a full body harness is used shall produce a maximum arrest force (MAF) of not more than 1,800 pounds (8.0kN) and shall bring the fall to a complete stop with a deceleration distance of not more than 42 inches (1,067 mm). In suspension, after the fall is arrested, the angle at rest which the vertical centerline of the test torso makes with the vertical shall not exceed 30 degrees.<\/p><p>3.2.1.4 Snap Hooks and carabiners shall be self closing and self locking and shall be capable of being opened only by at least two consecutive deliberate actions.<\/p><p>3.2.2.4 The harness shall provide support for the body across the lower chest, over the shoulders and around the thighs when a tensile load is applied to the fall arrest attachment elements. The harness, when properly fitted and used, shall prevent fall-out. The fall arrest attachment shall be located at the back (dorsal) position.<\/p><p>3.2.4.7 When energy absorbers are dynamically tested in accordance with 4.3.5.2, the maximum arrest force shall not exceed 900 lbs. (4 kN).<\/p><p>3.2.8.7 Static Strength- When tested in accordance with 4.3.7.3, the SRL shall withstand a tensile load of 3,000 pounds (13.3 kN) statically applied directly to the point of SRL line connection to the SRL drum.<\/p><p>3.2.8.9. Dynamic Performance- When tested in accordance with 4.3.7.1, the SRL shall lock and remain locked until released. The arrest distance shall not exceed 54 inches (1,372 mm). Maximum arrest force shall not exceed 1,800 pounds (8kN).<\/p><p>5.1.2 The legibility and attachment of required markings shall endure for the life of the component, subsystem, or system being marked.<\/p><p>5.3.1 Instructions shall be provided to the user, printed in English, and affixed to the equipment at the time of shipment from the manufacturer.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2245\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2245\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-right\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-angle-down\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M143 352.3L7 216.3c-9.4-9.4-9.4-24.6 0-33.9l22.6-22.6c9.4-9.4 24.6-9.4 33.9 0l96.4 96.4 96.4-96.4c9.4-9.4 24.6-9.4 33.9 0l22.6 22.6c9.4 9.4 9.4 24.6 0 33.9l-136 136c-9.2 9.4-24.4 9.4-33.8 0z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-angle-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M177 159.7l136 136c9.4 9.4 9.4 24.6 0 33.9l-22.6 22.6c-9.4 9.4-24.6 9.4-33.9 0L160 255.9l-96.4 96.4c-9.4 9.4-24.6 9.4-33.9 0L7 329.7c-9.4-9.4-9.4-24.6 0-33.9l136-136c9.4-9.5 24.6-9.5 34-.1z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">STRICT CONFORMANCE WARNING<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2245\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2245\"><p><strong>Strict Conformance Warning \u2013 Active &amp; Passive Fall Protection Systems<\/strong><\/p><blockquote><p><strong><em>\u201c<span style=\"color: #800000;\">!! CAUTION !! This is a fall protection system. The system must be used in strict conformance with the manufacturer\u2019s instructions. You can download the system manuals from the \u2018Downloads\u2019 tab on each product page OR provided to you in the proposal and order emails. Failure to do so may result in serious injury or death.<\/span><\/em><\/strong><\/p><p><strong><em><span style=\"color: #800000;\"> In the case of tie-off systems (active systems), do not use or operate this system unless you are properly trained. You are also encouraged to contact us in case of any questions.<\/span>\u201c<\/em><\/strong><\/p><\/blockquote><p>If perimeter platforms cannot be used, active systems can be installed, requiring the workers to don harnesses and connect to an overhead system. Active fall protection system options consist of fixed-point anchors, horizontal lifelines and conventional beam and trolley systems each attached to the existing overhead structure.<\/p><p>It is crucial that the authorized person\/user of this equipment read and understand these instructions. In addition, federal law requires employers to ensure that all users are trained in the proper installation, use, inspection, and maintenance of fall protection equipment. Fall protection training should be an integral part of a comprehensive safety program.<\/p><p>Proper use of fall arrest systems can save lives and reduce the potential of serious injuries from a fall. <strong>The user must be aware that forces experienced during the arrest of a fall or prolonged suspension may cause bodily injury.<\/strong> Consult a physician if there is any question about the user\u2019s ability to use this product. Pregnant women and minor children must not use this product.<\/p><p>According to OSHA, all workers exposed to falls <strong>should be trained<\/strong> by a <a href=\"https:\/\/caisafety.com\/caiss-staging\/fall-protection-training\/#competent-person\">competent person<\/a> to recognize fall hazards and to be familiar with available control methods and equipment.<\/p><p><strong>Questions?<\/strong> Contact us at (888) 246-6999 or email us at <a href=\"mailto:info@caisafety.com\">info@caisafety.com<\/a><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"GENERAL INFORMATION\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<div class=\\\"osha_img\\\"><img src=\\\"https:\\\/\\\/caisafety.com\\\/caiss-staging\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/ansi-logo2.png\\\" \\\/><\\\/div><p>The <a href=\\\"http:\\\/\\\/webstore.ansi.org\\\/safety_standards\\\/default.aspx?source=ohs\\\" target=\\\"_blank\\\" rel=\\\"noopener noreferrer\\\">American National Standards Institute (ANSI)<\\\/a> founded in 1918, coordinates the development of voluntary safety standards in the fall protection industry. Representing more than 3.5 million professionals ANSI is comprised of government agencies, organizations, academic and international bodies, and individuals. ANSI Fall Protection regulations are not law, but do provide guidelines that are frequently so practical and essential that they are adopted by OSHA and enforced legally.<\\\/p><p>ANSI Fall Protection consensus standard was originally published in 1992, and was aimed at providing safety requirements for personal fall arrest systems, subsystems and components. One of the most important issues they have brought to the forefront is the elimination of hazards in the fall protection products themselves. And each time ANSI undergoes a revision, they hold the manufacturers of fall protection products to a higher standard. For example, a connector gate face that was previously compliant at 220 lbs. now is held to 3,600 lbs. This ensures employers and employees that they not only have the highest quality products, but, as a result, the safest workplaces.<\\\/p><p>ANSI Fall Protection also provides standards for workplace training and appropriate methods for developing a fall protection plan. No other country has such a detailed and comprehensive standard that is specific to fall protection.<\\\/p>\"}},{\"@type\":\"Question\",\"name\":\"ANSI STANDARDS\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<table class=\\\"specs-tab1\\\" border=\\\"0\\\" width=\\\"100%\\\" cellspacing=\\\"0\\\" cellpadding=\\\"0\\\">\\n<tbody>\\n<tr>\\n<td width=\\\"460\\\">Construction and Demolition Operations: Requirements for Safety Belts, Harnesses, Lanyards &amp; Lifelines for Construction and Demolition<\\\/td>\\n<td width=\\\"250\\\">A10.14-1991<\\\/td>\\n<\\\/tr>\\n<tr>\\n<td width=\\\"460\\\">Ladders \\u2013 Fixed \\u2013 Safety Requirements<\\\/td>\\n<td width=\\\"250\\\">A14.3-1992<\\\/td>\\n<\\\/tr>\\n<tr>\\n<td width=\\\"460\\\">Safety Requirements for Confined Spaces<\\\/td>\\n<td width=\\\"250\\\">Z117.1-1989<\\\/td>\\n<\\\/tr>\\n<tr>\\n<td>Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components<\\\/td>\\n<td width=\\\"250\\\">Z359.1-1992<\\\/td>\\n<\\\/tr>\\n<\\\/tbody>\\n<\\\/table>\"}},{\"@type\":\"Question\",\"name\":\"ANSI FALL PROTECTION REGULATIONS & STANDARDS\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>Our ANSI\\u00a0compliant Fall Protection, Fall Arrest, and Fall Restraint Systems, including our Fall Protection Training &amp; Services, have been designed to provide ease of handling, installation and use without compromising safety.<\\\/p><p><strong>ANSI Website:<\\\/strong>\\u00a0<a href=\\\"https:\\\/\\\/webstore.ansi.org\\\/safety_standards\\\/default.aspx\\\" target=\\\"_blank\\\" rel=\\\"noopener noreferrer\\\">https:\\\/\\\/webstore.ansi.org\\\/safety_standards\\\/default.aspx<\\\/a><\\\/p>\"}},{\"@type\":\"Question\",\"name\":\"ANSI SAFETY REQUIREMENTS FOR PERSONAL FALL ARREST SYSTEMS, SUBSYSTEMS & COMPONENTS\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>1.2.1 This standard addresses only personal fall arrest systems (PFAS) incorporating full body harnesses. Whenever the term \\u201csystem\\u201d is used in the standard if refers to a personal fall arrest system.<\\\/p><p>3.1.2 When subjected to tests contained in 4.2, a personal <a href=\\\"https:\\\/\\\/caisafety.com\\\/caiss-staging\\\/mobile-fall-protection-systems\\\/\\\">fall arrest system<\\\/a> in which a full body harness is used shall produce a maximum arrest force (MAF) of not more than 1,800 pounds (8.0kN) and shall bring the fall to a complete stop with a deceleration distance of not more than 42 inches (1,067 mm). In suspension, after the fall is arrested, the angle at rest which the vertical centerline of the test torso makes with the vertical shall not exceed 30 degrees.<\\\/p><p>3.2.1.4 Snap Hooks and carabiners shall be self closing and self locking and shall be capable of being opened only by at least two consecutive deliberate actions.<\\\/p><p>3.2.2.4 The harness shall provide support for the body across the lower chest, over the shoulders and around the thighs when a tensile load is applied to the fall arrest attachment elements. The harness, when properly fitted and used, shall prevent fall-out. The fall arrest attachment shall be located at the back (dorsal) position.<\\\/p><p>3.2.4.7 When energy absorbers are dynamically tested in accordance with 4.3.5.2, the maximum arrest force shall not exceed 900 lbs. (4 kN).<\\\/p><p>3.2.8.7 Static Strength- When tested in accordance with 4.3.7.3, the SRL shall withstand a tensile load of 3,000 pounds (13.3 kN) statically applied directly to the point of SRL line connection to the SRL drum.<\\\/p><p>3.2.8.9. Dynamic Performance- When tested in accordance with 4.3.7.1, the SRL shall lock and remain locked until released. The arrest distance shall not exceed 54 inches (1,372 mm). Maximum arrest force shall not exceed 1,800 pounds (8kN).<\\\/p><p>5.1.2 The legibility and attachment of required markings shall endure for the life of the component, subsystem, or system being marked.<\\\/p><p>5.3.1 Instructions shall be provided to the user, printed in English, and affixed to the equipment at the time of shipment from the manufacturer.<\\\/p>\"}},{\"@type\":\"Question\",\"name\":\"STRICT CONFORMANCE WARNING\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p><strong>Strict Conformance Warning \\u2013 Active &amp; Passive Fall Protection Systems<\\\/strong><\\\/p><blockquote><p><strong><em>\\u201c<span style=\\\"color: #800000;\\\">!! CAUTION !! This is a fall protection system. The system must be used in strict conformance with the manufacturer\\u2019s instructions. You can download the system manuals from the \\u2018Downloads\\u2019 tab on each product page OR provided to you in the proposal and order emails. Failure to do so may result in serious injury or death.<\\\/span><\\\/em><\\\/strong><\\\/p><p><strong><em><span style=\\\"color: #800000;\\\"> In the case of tie-off systems (active systems), do not use or operate this system unless you are properly trained. You are also encouraged to contact us in case of any questions.<\\\/span>\\u201c<\\\/em><\\\/strong><\\\/p><\\\/blockquote><p>If perimeter platforms cannot be used, active systems can be installed, requiring the workers to don harnesses and connect to an overhead system. Active fall protection system options consist of fixed-point anchors, horizontal lifelines and conventional beam and trolley systems each attached to the existing overhead structure.<\\\/p><p>It is crucial that the authorized person\\\/user of this equipment read and understand these instructions. In addition, federal law requires employers to ensure that all users are trained in the proper installation, use, inspection, and maintenance of fall protection equipment. Fall protection training should be an integral part of a comprehensive safety program.<\\\/p><p>Proper use of fall arrest systems can save lives and reduce the potential of serious injuries from a fall. <strong>The user must be aware that forces experienced during the arrest of a fall or prolonged suspension may cause bodily injury.<\\\/strong> Consult a physician if there is any question about the user\\u2019s ability to use this product. Pregnant women and minor children must not use this product.<\\\/p><p>According to OSHA, all workers exposed to falls <strong>should be trained<\\\/strong> by a <a href=\\\"https:\\\/\\\/caisafety.com\\\/caiss-staging\\\/fall-protection-training\\\/#competent-person\\\">competent person<\\\/a> to recognize fall hazards and to be familiar with available control methods and equipment.<\\\/p><p><strong>Questions?<\\\/strong> Contact us at (888) 246-6999 or email us at <a href=\\\"mailto:info@caisafety.com\\\">info@caisafety.com<\\\/a><\\\/p>\"}}]}<\/script>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>ANSI Fall Protection Regulations &amp; Standards ANSI website GENERAL INFORMATION The American National Standards Institute (ANSI) founded in 1918, coordinates the development of voluntary safety standards in the fall protection industry. Representing more than 3.5 million professionals ANSI is comprised of government agencies, organizations, academic and international bodies, and individuals. ANSI Fall Protection regulations are [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-11492","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ANSI Fall Protection Regulations &amp; Standards \u2013 CAI Safety<\/title>\n<meta name=\"description\" content=\"The American National Standards Institute (ANSI) is aimed at providing safety requirements for personal fall arrest systems, and subsystems to ensure worker protection.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/\",\"url\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/\",\"name\":\"ANSI Fall Protection Regulations & Standards \u2013 CAI Safety\",\"isPartOf\":{\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png\",\"datePublished\":\"2017-04-18T17:28:04+00:00\",\"dateModified\":\"2025-10-14T11:19:09+00:00\",\"description\":\"The American National Standards Institute (ANSI) is aimed at providing safety requirements for personal fall arrest systems, and subsystems to ensure worker protection.\",\"breadcrumb\":{\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#primaryimage\",\"url\":\"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png\",\"contentUrl\":\"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png\",\"width\":210,\"height\":82,\"caption\":\"ANSI Fall Protection\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/caisafety.com\/caiss-staging\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ANSI Fall Protection Regulations &#038; Standards\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/#website\",\"url\":\"https:\/\/caisafety.com\/caiss-staging\/\",\"name\":\"CAI Safety Systems, Inc.\",\"description\":\"Custom Engineered &amp; Off-the-shelf Fall Protection Solutions\",\"publisher\":{\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/#organization\"},\"alternateName\":\"CAISS\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/caisafety.com\/caiss-staging\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/#organization\",\"name\":\"CAI Safety Systems, Inc.\",\"url\":\"https:\/\/caisafety.com\/caiss-staging\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2021\/06\/CAI-Safety-Systems-Inc-Logo.jpg\",\"contentUrl\":\"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2021\/06\/CAI-Safety-Systems-Inc-Logo.jpg\",\"width\":600,\"height\":240,\"caption\":\"CAI Safety Systems, Inc.\"},\"image\":{\"@id\":\"https:\/\/caisafety.com\/caiss-staging\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/caisafety\/\",\"https:\/\/x.com\/CAISafety\",\"https:\/\/www.linkedin.com\/company\/cai-safety-systems\",\"https:\/\/www.pinterest.com\/caisafety\/\",\"https:\/\/www.youtube.com\/channel\/UCLEtqCX5uQHhMoKWMrZT8pw\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ANSI Fall Protection Regulations & Standards \u2013 CAI Safety","description":"The American National Standards Institute (ANSI) is aimed at providing safety requirements for personal fall arrest systems, and subsystems to ensure worker protection.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/","url":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/","name":"ANSI Fall Protection Regulations & Standards \u2013 CAI Safety","isPartOf":{"@id":"https:\/\/caisafety.com\/caiss-staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#primaryimage"},"image":{"@id":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#primaryimage"},"thumbnailUrl":"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png","datePublished":"2017-04-18T17:28:04+00:00","dateModified":"2025-10-14T11:19:09+00:00","description":"The American National Standards Institute (ANSI) is aimed at providing safety requirements for personal fall arrest systems, and subsystems to ensure worker protection.","breadcrumb":{"@id":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#primaryimage","url":"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png","contentUrl":"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2018\/10\/ansi-logo2.png","width":210,"height":82,"caption":"ANSI Fall Protection"},{"@type":"BreadcrumbList","@id":"https:\/\/caisafety.com\/caiss-staging\/ansi-fall-protection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/caisafety.com\/caiss-staging\/"},{"@type":"ListItem","position":2,"name":"ANSI Fall Protection Regulations &#038; Standards"}]},{"@type":"WebSite","@id":"https:\/\/caisafety.com\/caiss-staging\/#website","url":"https:\/\/caisafety.com\/caiss-staging\/","name":"CAI Safety Systems, Inc.","description":"Custom Engineered &amp; Off-the-shelf Fall Protection Solutions","publisher":{"@id":"https:\/\/caisafety.com\/caiss-staging\/#organization"},"alternateName":"CAISS","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/caisafety.com\/caiss-staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/caisafety.com\/caiss-staging\/#organization","name":"CAI Safety Systems, Inc.","url":"https:\/\/caisafety.com\/caiss-staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/caisafety.com\/caiss-staging\/#\/schema\/logo\/image\/","url":"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2021\/06\/CAI-Safety-Systems-Inc-Logo.jpg","contentUrl":"https:\/\/caisafety.com\/caiss-staging\/wp-content\/uploads\/2021\/06\/CAI-Safety-Systems-Inc-Logo.jpg","width":600,"height":240,"caption":"CAI Safety Systems, Inc."},"image":{"@id":"https:\/\/caisafety.com\/caiss-staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/caisafety\/","https:\/\/x.com\/CAISafety","https:\/\/www.linkedin.com\/company\/cai-safety-systems","https:\/\/www.pinterest.com\/caisafety\/","https:\/\/www.youtube.com\/channel\/UCLEtqCX5uQHhMoKWMrZT8pw"]}]}},"_links":{"self":[{"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/pages\/11492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/comments?post=11492"}],"version-history":[{"count":0,"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/pages\/11492\/revisions"}],"wp:attachment":[{"href":"https:\/\/caisafety.com\/caiss-staging\/wp-json\/wp\/v2\/media?parent=11492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}